Course start time: December 31, 2022 - May 6, 2022 Lecturer: Ma Haibo Class time: Morning: 9:50~12:00 Afternoon: 13:20 ~17:20

QYTangCiscoData CenterData Center 3.0 Eighth Course Schedule (Saturday Class)

Course start time: December 31, 2022 - May 6, 2022

Lecturer: Ma Haibo

Class hours:

Morning: 9:50~12:00

Afternoon: 13:20 ~17:20

 

《CiscoNexus Switch》

 

December 31

Cisco data legacy center network architecture,

Nexus series product line,

Product introduction of Nexus 7K series,

Nexus series switch port density,

Introduction to Nexus series switch management engine,

Supervisor 3E engine of N77 series,

Virtual Output Queues,

Nexus series switch management connection mode,

Nexus 7000 product label naming rules

Nexus 7K Ethernet I/O module classification

Nexus 7K Ethernet M-Series Module

Nexus 7000 M2 I/O Module

Nexus 7000/7700 M3 I/O modules

Nexus 7K Ethernet F-Series Module

Nexus 7000 F3 I/O Modules

Fabric Services Accelerator (FSA) for F3 / M3

F3 card traffic forwarding

Nexus 7700 F4 I/O Modules

I/O Modules Interactive Mode

Proxy Forwarding method

Lowest Common Denominator approach

F/M Card Hardware Table Capacity Comparison

Crossbar Switch Fabric Module

Nexus 7000 Fabric Module (1)

Nexus 7700 Fabric 2 Module

multi-layer switching matrix

Layer 2 Hardware Forwarding

MAC Table Lookup

Layer 3 Hardware Forwarding

IP FIB TCAM Lookup

Power supply: 6KW AC

Power supply: 7.5KW AC

Power supply: 6KW DC

Power supply non-redundant mode and correct wiring

Power redundancy (N+1 Redundancy)

Grid Redundancy

Power redundancy (Full Redundancy)

Cisco NX-OS Module Architecture

Nexus 7000 / Nexus 7700 NX-OS Features Overview

Virtualization of Cisco NX-OS

Continuous Operations/HA for Cisco NX-OS

Security of Cisco NX-OS

Operational Manageability of Cisco NX-OS

Cisco NX-OS L4-7 Services Integration

Cisco NX-OS Licensing (1)

Cisco NX-OS License Ordering Information

Cisco NX-OS authorization application and activation

N5000/6000Data Center aggregation access layer switch

Nexus 5500/5600/6000 usage scenarios

Nexus 5672UP

Nexus 5500 Data and Control Plane Elements

Nexus 5500 Data Plane Elements

Nexus 5500 control plane components

NEXUS 5672UP internal structure

Nexus 5600 Key Forwarding Tables

Nexus 5600 Unicast Table Scaling

Host Table Carving Profiles

MAC/ARP Resource Carving CLI

NEXUS 5600 Series Comparison

NEXUS 5600/6000 Summary

N2K Fabric Extender(FEX)

Cisco Nexus 2000 Series

Nexus 2232PP-10G Fabric Extender

N2K naming method

Fabric Extender terminology

Introduction to packet sending (VN-Tag technology)

Nexus 2000 topology

View module status and version information

Configure management IP address

Configure CDP

Configure power redundancy

Configure NTP (Default VDC)

Configure NTP (None-Default VDC)

Cisco Fabric Services

Configure CFS to synchronize NTP

Introduction to Scheduler

Configure Scheduler

Introduction to Ethanalyzer

Configure Ethanalyzer

Introduction to Rollback

Configure Rollback

Activate password strength check

Configure SSH server

SSH client

Introduction to CoPP

Introduction to SMARTnet

Introduction to Call home

Alert Group  

The types of events that trigger alerts 

Configure Call home

Cisco VDC architecture

Linux kernel namespace mechanism

Virtualization scalability

Default VDC

Non-Default VDC Ordinary VDC

Admin VDC

VDC fault domain

VDC resource object

VDC resource sharing

Storage VDC

VDC module association restrictions

N7K-M132XP-12 Port Group Introduction

N7K-F132XP-15 Port Group Introduction

Communication between VDCs

VDC Resource Template

VDC hardware utilization: Layer 2 switching

VDC hardware utilization: three-layer switching

Out-of-band VDC management

In-band VDC management

Configure Resource Template

Create VDC

Limit VDC resource usage

Limit associated modules

Associate the interface to the VDC (DC2-N7K-3

CPU Share

Configure CPU Share

Configure Boot Order

Introduction to VDC High Availability (1)

Configure VDC high availability

Convert Default VDC to Admin VDC

Switching between VDCs

 

January 07

The default mode of the port

Basic interface configuration experiment

N7K basic interface configuration

N5K basic interface configuration

Interface description and beacon

MTU configuration introduction

Configure MTU

Understand UDLD technology

ConfigureUDLD

Simulate UDLD failure

UDLD considerations

Configure OSPF on DC1-N7K-3

The IP unnumbered feature

Configuring BFD technology for OSPF

Establishment of BFD neighbor relationship

BFD theory introduction

Introduction to PSS

Introduction of Graceful Restart

Configure Trunk, VLAN and VTP on DC1-N7K-1

Configure Trunk and VTP on DC1-N5K-1

Adjust STP

Configure MST

Configure HSRP and VRRP

Summary of L2/L3 knowledge points

Cisco Nexus switches use Fabric Extenders

Top of Rack wiring and End of Row management

Cisco Nexus 7000 FEX-enabled modules

Cisco Nexus 9000 FEX-enabled modules

Nexus 2348UPQ Overview

Nexus 2232PP-10GE Fabric Extender

Introduction to the package sending process

Network Interface Virtualization (NIV) architecture

VN-Tag port extension

Cisco N7K FEX and VDC

Nexus 2000 SPAN

Introduction to Staic Pinning

Introduction to EtherChannel

Rules for port commands

FEX topology supported by N7K and N5K

N5K FEX Experiment 1: Single-host FEX (Static Pinning)

N5K FEX Experiment 2: Single-host FEX (EtherChannel)

 

 

 

February 18

Introduction to Port Channel

Port Channel mode

Hash Options

Experiment 1: Switchport Access

Experiment 2:Switchport Trunk

Experiment 3:Routed Interface

Experiment 4:Routed subinterfaces

Introduction to vPCs

STP vs vPC

Up to 32 Port-Channels (Double-Sided vPC)

Components of vPC Architecture (1)

Components of vPC Architecture (2)

Components of vPC Architecture (3)

Configure vPC principles

vPC and N7K module design drawing

vPC control plane operations

vPC data plane operations

Data layer loop prevention (vPC Check)

vPC Peer Link Device Failure

vPC Peer Failure — Peer-keepalive Link

Configure vPCs

Experiment 5: N7K vPC (topology introduction)

Experiment 5: Configuring HSRP

vPC and STP BPDU

Spanning Tree Recommended

Adjust Spanning Tree configuration

vPC Peer Switch feature introduction

Autorecovery

Delay Restore

vPC Object Tracking

ARP Synchronization

vPC Peer-Gateway

Configuring N5K vs N7K vPC

Configure EvPC

vPC Domain

System MAC

vPC Role

Introduction to vPC Peer Link

vPC Member Port Introduction

vPC and VDC

Interaction between Layer 3 and vPC

Layer 3 and vPC design

Layer 3 and vPC supported designs

Interoperability between STP and vPC

Multi-layer vPC and Data Center interconnect

FHRP and vPC

Orphan-Port Suspend

Design of vPC and FEX

Switch Port Analyzer (SPAN)

Encapsulated Remote SPAN (ERSPAN)

ERSPAN configuration

Introduction to NetFlow

NetFolw configuration

 

February 25

 

What are Overlays

OverlaysVirtualization Types

VXLAN Overview 

VXLAN Frame Format 

VXLAN VTEP

VXLAN Underlay Network – IP Routing

VXLAN Forwarding Plane

VXLAN Forwarding Packet 

VXLAN BUM Traffic Handling

VTEP Discovery & Address Learning 

Challenges with Flood-&-Learn VXLAN Deployments

What is VXLAN/EVPN

Functions of VXLAN/EVPN

VXLAN: Flood-&-Learn vs EVPN Control Plane

EVPN Primer --- MP-BGP Review

EVPN Control Plane – Reachability Distribution

EVPN Control Plane -- Host Advertisement

EVPN Control Plane -- Host Movement

Distributed Anycast Gateway in MP-BGP EVPN

VXLAN Routing

Symmetric Integrated Routing & Bridging (IRB)

Packet Forwarding (Bridge) 

Packet Forwarding (Route) 

EVPN Control Plane -- ARP Suppression

EVPN Control Plane -- Head-end Replication

Flood-&-Learn  VS  EVPN Control Plane 

 

March 04

VxLAN EVPN Parameters

Route Distinguishers (RDs).

Route Target (RT)

EVPN Route types

Route type 2 (MAC Only)

Route type 2 (MAC/IP)

Inclusive Multicast

Route type 5 (IP)

Route type 5 (IP) has two uses

Sample EVPN-Related VRF Configuration for Layer 3 Multitenancy

ARP lookup miss with ARP Suppression

Multi-pod

Multi-fabric/Multi-site

Interfabric Option 1: Multi-pod

Interfabric Option 2: Multifabric

Interfabric Option 3 (Multisite for Layer 3)

Interfabric Option 4 (Multisite for Layer 2)

VXLAN EVPN MultiPod experimental topology

Loopback configuration

Interface configuration

Ospf routing configuration

Pim multicast configuration

MP-BGP configuration

VXLAN related configurations

 

March 11

VXLAN Evolves as the Control Plane Evolves

Inter-X Connectivity

Multi-Pod Characteristics – ”The Single”

Multi-Pod End-to-End Encapsulation

Multi-Pod VXLAN Tunnel Adjacencies

Multi-Pod Underlay Extension

Multi-Pod BUM Replication

Multi-Pod Challenges – ”The Single”

Multi-Site Overlay Forwarding

VXLAN Multi-Site

VXLAN Multi-Site Characteristics

VXLAN Multi-Site Underlay Isolation

Introducing the Border Gateway

VXLAN Tunnel Adjacencies

HW/SW Support and Scalability Values

BGW-to-Cloud

Anycast Border Gateway

BUM Replication Modes

Control Plane Deployment Considerations

Overlay Control Plane (L3 Core, no RS)

Selective Advertisements

Multi-Site Packet Walk (BUM)

VXLAN Multi-Site Packet Walk(Bridging)

VXLAN Multi-Site Packet Walk(Routing)

VXLAN Multi-Site Topology

VXLAN Multi-Site Configuration

VXLAN Multi-Site dual BGW scenario

VXLAN Multi-Site PIP and VIP

VXLAN Multi-Site Route-Type 4 

VXLAN Multi-Site Route-Type 3

VXLAN Multi-Site Fabric link failure

VXLAN Multi-Site DCI link failure

Implement Route Leaking between different VXLAN tenants (added in the previous issue, no longer discussed separately)

《CiscoNexus 9000 ACI Architecture》

 

March 18

Software Defined Networking (SDN(X))

SDN from different manufacturers

Misunderstandings about SDN

Two different network needs

ACI Data Center Product

Cisco ACI technical analysis

SDN market forecast

About the definition of SDN

Three major SDN standardization organizations

What is OpenFlow

Cisco challenges and opportunities

SDN architecture core components

Problems solved by SDN and OpenFlow

Limitations of OpenFlow

SDN three main components and goals

NFV overview

ETSI NFV Reference Architecture

Division of labor between NFV and SDN

Application examples of SDN in NFV architecture

Comprehensive SDN solution

Cisco One Solutions

Cisco ACI Data Center

Problems faced when deploying applications

Policy Driven Data Center Approach

ACI Fabric Interconnect Matrix

Application Definition

Example of an “Application”

The Policy Theory 

ACI Logical Architecture

Relationship between Consumer and Provider

ACI Fabric Design

Data center network characteristic

Spine-Leaf Architecture

Why Spine and Leaf

IS-IS Fabric Infrastructure Routing

VXLAN Overlay overlay network

ACI VXLAN Header 

Additional ACI VXLAN Header Details 

VXLAN Tunnel Endpoint (VTEP)

ACI Fabric Addressing 

ACI Fabric Integrated Overlay

Decoupled Identity,Location, and Policy

Leaf Packet Flow

Distributed Forwarding Control Plane - Station Tables

Layer 2 and Layer 3 Handing

Hardware-based Directed ARP Forwarding

Gratuitous ARP and Device Movement

Forwarding Bounce

ACI Fabric Unicast Forwarding Overview

Fast Re-Route  Unicast

ACI Fabric Multicast Forwarding Overview

Endpoint  Learning & Lookup

EPG Operational Tab - Client Endpoints

EPG Operational Tab - Global Endpoints

Endpoint Identity Location Learning Example

ACI Policy Identification and Enforcement

Nexus 9000 Platform: Two Modes

Merchant and Custom ASICs

Nexus 9508 Hardware Overview

Nexus 9500 Platform System Controller

Nexus 9500 Platform Supervisor

Hardware 8-Slot Modular Chassis Air Flow

Fabric Module – Data Plane Scaling for 8-Slot Chassis

Deployment of Line Cards in the ACI Fabric

Cisco Nexus ACI Modular Line Cards

Cisco Nexus ACI Modular Line Cards - Reference

Cisco Nexus 9300 Spine Platform

Cisco Nexus 9300 Leaf Platform

ACI Customer Bundles Configuration

Switch Installation best practices

 

March 25

What is APIC

APIC controller is attached in-band

APIC Clustering -Sharding Technology

Effect of Sharding on Reliability

APIC Clustering

RESTful API Overview

Creating an App Network Profile

APIC Hardware Ports

Fabric Initialization & Maintenance

Fabric Login

Fabric GUI overview

Fabric Initialization & Maintenance

ACI Initial Configuration Steps

Management Networks

Configure OOB and Inband MGMT

Configure NTP

ACI Policy Types

Fabric Policy and Access Policy

External interface configuration

Configure interface policy

Configure interface policy group

Configure interface profile

Configure switch profile

Configure ACI Pools

Configure VLANs Pool

EPG Mapped to Multiple Ports and VLANs

Configure Physical and External Domain

Concept of Domain

Configure Physical Domain

Configure Attachable Entity Profile (AEP)

Configure AEP with Interface Policy Group

Configure vPC in ACI Fabric

ACI logical model

Application Network Profiles (ANP)

ACI Connection to Outside Network

Extend L2 Domain Out of ACI

Option A: Extend EPG

Option B: Extend Bridge Domain

ACI L2 External Connection - STP Interaction

ACI Layer 3 outside connections

Border Leaves

Route Distribution within the ACI Fabric

OSPF Peering between ACI and the External Router

OSPF High-Availability Design

Layer 3 Outside Connection with OSPF Example

Integrate L4-L7 Service Graphs

Service Graph Definition

ACI Terminology

With service graph the operational model changes

How to Use Sevice Graph

Device Definition and Package

 

 

 

April 01

Clear APIC existing configuration

Clear the existing configuration of leaf1

Clear the existing configuration of spine1

Initialize APIC configuration

Register Leaf and Spine nodes

Configure Leaf and Spine node management addresses

Configure Leaf and Spine NTP addresses

Application layer top-down design

Overall design of application layer

Application layer requirements

Restore APIC empty configuration

Create tenant and VRF

Create bridge domain T1-BD1

Create T1 tenant HTTP contract

Create Common tenant ICMP contract

Create T1-ANP under T1 tenant

EPG access relationship diagram

Register to APIC via vCenter domain

Configuring Vmware ESXi host to use APIC's DVS

Configure the interface AEP connected to the host

Associate EPG to Vmware vCenter Domain

Associating the VM to the Port Group of the EPG

Test ping Gateway

Configuration of OSPF and Interface on DC2-N7K2

Enable MP-BGP in ACI Fabric

Determine to create an AEP for the port connected to the N7K based on the situation.

Create L3Out external network (EPG of type L3Out)

Establish OSPF neighbor with N7K

L3Out EPG call accesses the contract of EPG NGINX

Implementation of multi-tenant and multi-tier application interoperability

Added ACI's Multi-Pod theoretical and experimental explanations

"Cisco Storage Network"

 

April 8

SAN, LAN, and Compute

Cisco’s Commitment to FC

Cisco MDS 9706, 9710 and 9718 Product Portfolio

Unmatched Flexibility with Multi-Protocol Innovations

Boosting Scale for SAN InfrastructuresThousands of Devices

Cisco MDS 9710 Multilayer Director

Cisco MDS 9000 16G Fibre Channel Family

MDS 9250i Multiservice Fabric Switch

Cisco Nexus 5672UP-16G

Evolving the Datacenter in Phases

MDS 9718 USE CASE

CISCO 40G QSFP BIDITRANSCEIVERS

40GE ISL USE CASE

Large-Scale Converged Ethernet Deployments

The Power of Ecosystem

History of storage technology development

What are DAS, NAS and SAN

hard disk interface protocol

NAS architecture

Block I/O vs. File I/O

Block-Based Protocols

SCSI Overview

SCSI protocol

Storage Area Network (SAN)

Storage protocol technology diagram

Fibre Channel Overview

Standard FC port type

Fiber Channel physical address

Addressing FCID

well-known address

N_Port Virtualization(NPIV)

N Port Virtualization(NPV)

NPV and NPIV relationship

FC frame header structure

Detailed introduction to FC header field

Fiber Channel FC-2 Layer

Fiber Channel frame structure

Ethernet flow control

Fibre Channel Flow Control

Fabric Login(FLOGI)

Port Login(PLOGI)

Process Login(PRLI)

Fabric Short Path First

Load Balancing over equal cost paths

Common Design Practice - Redundant Fabrics

Virtual SANs (VSANs)

Two Primary Functions of VSANs

VSANs and Zones

FC configuration experimental part

 

 

 

April 15

The Evolving Data Center Architecture

FC over Ethernet (FCoE) 

FCoE Enables Unified Fabric 

Before I/O Consolidation

After I/O Consolidation

High-Speed Ethernet Server Adoption

No packet loss using PAUSE technology (802.3x)

Data Center Bridging four major component technologies

Priority Flow Control 

Enhanced Transmission Selection

DCBX: Data Center Bridging eXchange

BCN/QCN

FCoE Mapping

FCoE packaging

FCoE and FIP

Fibre Channel Forwarder 

Fibre Channel Port Types

Introduction to FIP

Comparison of FC and FCoE configuration examples

FIP Virtual Link Establishment

FIP VLAN Discovery

FIP VLAN Request

FIP VLAN Response

FIP FCF Discovery

FIP FCF discovery solicitation

FIP Virtual Link Instantiation

FIP FLOGI Request

FIP FLOGI ACC

FIP Virtual Link Maintenance

FIP KeepAlive

FCF MAC address

FPMAs and SPMAs

FCoE interface diagram

What is FCoE-NPV 

FCoE-NPV configuration Details 

Single Hop Design-OverView 

Single Hop Design - The CNA Point of View 

Single Hop Design- The FCoE VLAN  

Single Hop Design - Converged Links and vPC 

Multi - Hop Design 

FCoE configuration experimental part

Configure VFC

Configure the FCoE link between N5K1 and N5K3

Configure the zone between N5K1 and N5K3

"CiscoUCS Unified Computing System"

 

April 22

Server deployment: rack-mounted

Server deployment: Blade

Blade Server Deployment: Management

Blade Server Deployment: Applications

Server deployment virtualization

Cisco's solution

Traditional blade server architecture

Cisco Unified Computing System UCS

One of the important innovations: embedded management

Important innovation two: Unified Fabric

Important innovation three: optimized virtualization environment

Important Innovation Four: Memory Expansion Technology

Important Innovation No. 5: Stateless Server

Important Innovation Six: Hybrid Server

Introduction to UCS components

UCS series overall architecture

UCS Fabric Interconnects

Fabric Interconnects-6300 Series

Fabric Interconnects-6400 Series

Fabric Extender

Fabric Extender – 2304XP

Fabric Extender detailed introduction

Blade Servers: UCS B-Series

Chassis – 5108

Back of UCS system

UCS system front

UCS architecture physical view

UCS architecture logical view

Blade Servers: UCS B-Series

Rack Servers: UCS C-Series

Server Adaper

Cisco UCS VIC 1340

Cisco UCS VIC 1227

UCS S3260 Storage Server

Cisco UCS E-Series Servers

UCS simulator installation and initialization

UCS simulator download address

UCS simulator initialization

UCS simulator basic options

Configure Fabric Interconnect

Configuring FI for high availability

Login to UCSM

 

April 29

High availability FI connection

High availability cluster

High availability cluster initialization

Equipment panel

Servers panel

LAN panel

SAN panel

VM panel

Admin panel

Global Policies

Chassis Discovery Policy

Power Policy

Configure DNS

Configure time zone and NTP

Configure Server Port

Discover B200M2

Ethernet End Host Mode

disjoint layer-2

Soft-Pinning

Hard-Pinning

EHM sending rules

Ethernet Switching Mode

Uplink Configuration Guide

UCSM creates VLAN

Create Port-Channel (FI-A)

Configure LAN Uplinks Manager

UCS supported storage

FC End-Host Mode

Create VSAN and VLAN

FC link configuration between devices

Configure FI-A Uplink

Configure FCoE Uplink

Create UUID Pools

Create MAC Address Pools

Create WWNN Pools

Create WWPN Pools

Create Management IP Address Pool

Create Server Pools

May 06

Service Profile

Opt-In Models

Identify Service Profile

Storage

Networking

SAN  Connectivity

vNIC/vHBA Placement

vMedia Policy

Server Boot Order

Determine Target PWWN

Maintenance Policy

Operational Policies

Associate Service Profile to the server

N5K3 Zone configuration

Open-E configuration

SANBOOT started successfully

Service Profile Template

Organizational Relationships and Strategy Design

Two types of Templates

Install B200M2 ESXi

Configure B200M2 vSwitch1

 

CiscoData Center3.0 update announcement: Video summary network disk directory (DC high-quality group announcement has a link address)

How to learn Cisco Data Center 3.0 quickly and effectively: Video summary in the network disk directory

The following extended course video courses (only for through train students) require additional time to study by yourself;

"VMware vSphere 7.0 Virtualization" ---- A must-learn course before taking the main course!

"VMware NSX Network Virtualization"

"Cisco HyperFlex Hyperconvergence"

"Open Source KVM Virtualization"

"LISP in SDA" ---- Recommended learning

"Cloud Management Platform OpenStack Deployment"

"F5 Application Delivery Network 2020 Edition" ---- Key recommended learning

"Docker & Kubernetes 2021 Edition" has now been added to the through-train expansion course ---- Highly recommended learning

The latest recording of "SDN OpenFlow + OpenDaylight 2022 Edition"

QYTang customer service hotline: 400-618-8070

QYTang official website: www.qytang.com

QYTang Network Lab We think more for you