Course start time: December 31, 2022 - May 6, 2022 Lecturer: Ma Haibo Class time: Morning: 9:50~12:00 Afternoon: 13:20 ~17:20
QYTangCiscoData CenterData Center 3.0 Eighth Course Schedule (Saturday Class)
Course start time: December 31, 2022 - May 6, 2022
Lecturer: Ma Haibo
Class hours:
Morning: 9:50~12:00
Afternoon: 13:20 ~17:20
December 31 | Cisco data legacy center network architecture, Nexus series product line, Product introduction of Nexus 7K series, Nexus series switch port density, Introduction to Nexus series switch management engine, Supervisor 3E engine of N77 series, Virtual Output Queues, Nexus series switch management connection mode, Nexus 7000 product label naming rules Nexus 7K Ethernet I/O module classification Nexus 7K Ethernet M-Series Module Nexus 7000 M2 I/O Module Nexus 7000/7700 M3 I/O modules Nexus 7K Ethernet F-Series Module Nexus 7000 F3 I/O Modules Fabric Services Accelerator (FSA) for F3 / M3 F3 card traffic forwarding Nexus 7700 F4 I/O Modules I/O Modules Interactive Mode Proxy Forwarding method Lowest Common Denominator approach F/M Card Hardware Table Capacity Comparison Crossbar Switch Fabric Module Nexus 7000 Fabric Module (1) Nexus 7700 Fabric 2 Module multi-layer switching matrix Layer 2 Hardware Forwarding MAC Table Lookup Layer 3 Hardware Forwarding IP FIB TCAM Lookup Power supply: 6KW AC Power supply: 7.5KW AC Power supply: 6KW DC Power supply non-redundant mode and correct wiring Power redundancy (N+1 Redundancy) Grid Redundancy Power redundancy (Full Redundancy) Cisco NX-OS Module Architecture Nexus 7000 / Nexus 7700 NX-OS Features Overview Virtualization of Cisco NX-OS Continuous Operations/HA for Cisco NX-OS Security of Cisco NX-OS Operational Manageability of Cisco NX-OS Cisco NX-OS L4-7 Services Integration Cisco NX-OS Licensing (1) Cisco NX-OS License Ordering Information Cisco NX-OS authorization application and activation N5000/6000Data Center aggregation access layer switch Nexus 5500/5600/6000 usage scenarios Nexus 5672UP Nexus 5500 Data and Control Plane Elements Nexus 5500 Data Plane Elements Nexus 5500 control plane components NEXUS 5672UP internal structure Nexus 5600 Key Forwarding Tables Nexus 5600 Unicast Table Scaling Host Table Carving Profiles MAC/ARP Resource Carving CLI NEXUS 5600 Series Comparison NEXUS 5600/6000 Summary N2K Fabric Extender(FEX) Cisco Nexus 2000 Series Nexus 2232PP-10G Fabric Extender N2K naming method Fabric Extender terminology Introduction to packet sending (VN-Tag technology) Nexus 2000 topology View module status and version information Configure management IP address Configure CDP Configure power redundancy Configure NTP (Default VDC) Configure NTP (None-Default VDC) Cisco Fabric Services Configure CFS to synchronize NTP Introduction to Scheduler Configure Scheduler Introduction to Ethanalyzer Configure Ethanalyzer Introduction to Rollback Configure Rollback Activate password strength check Configure SSH server SSH client Introduction to CoPP Introduction to SMARTnet Introduction to Call home Alert Group The types of events that trigger alerts Configure Call home Cisco VDC architecture Linux kernel namespace mechanism Virtualization scalability Default VDC Non-Default VDC Ordinary VDC Admin VDC VDC fault domain VDC resource object VDC resource sharing Storage VDC VDC module association restrictions N7K-M132XP-12 Port Group Introduction N7K-F132XP-15 Port Group Introduction Communication between VDCs VDC Resource Template VDC hardware utilization: Layer 2 switching VDC hardware utilization: three-layer switching Out-of-band VDC management In-band VDC management Configure Resource Template Create VDC Limit VDC resource usage Limit associated modules Associate the interface to the VDC (DC2-N7K-3 CPU Share Configure CPU Share Configure Boot Order Introduction to VDC High Availability (1) Configure VDC high availability Convert Default VDC to Admin VDC Switching between VDCs |
January 07 | The default mode of the port Basic interface configuration experiment N7K basic interface configuration N5K basic interface configuration Interface description and beacon MTU configuration introduction Configure MTU Understand UDLD technology ConfigureUDLD Simulate UDLD failure UDLD considerations Configure OSPF on DC1-N7K-3 The IP unnumbered feature Configuring BFD technology for OSPF Establishment of BFD neighbor relationship BFD theory introduction Introduction to PSS Introduction of Graceful Restart Configure Trunk, VLAN and VTP on DC1-N7K-1 Configure Trunk and VTP on DC1-N5K-1 Adjust STP Configure MST Configure HSRP and VRRP Summary of L2/L3 knowledge points Cisco Nexus switches use Fabric Extenders Top of Rack wiring and End of Row management Cisco Nexus 7000 FEX-enabled modules Cisco Nexus 9000 FEX-enabled modules Nexus 2348UPQ Overview Nexus 2232PP-10GE Fabric Extender Introduction to the package sending process Network Interface Virtualization (NIV) architecture VN-Tag port extension Cisco N7K FEX and VDC Nexus 2000 SPAN Introduction to Staic Pinning Introduction to EtherChannel Rules for port commands FEX topology supported by N7K and N5K N5K FEX Experiment 1: Single-host FEX (Static Pinning) N5K FEX Experiment 2: Single-host FEX (EtherChannel)
|
February 18 | Introduction to Port Channel Port Channel mode Hash Options Experiment 1: Switchport Access Experiment 2:Switchport Trunk Experiment 3:Routed Interface Experiment 4:Routed subinterfaces Introduction to vPCs STP vs vPC Up to 32 Port-Channels (Double-Sided vPC) Components of vPC Architecture (1) Components of vPC Architecture (2) Components of vPC Architecture (3) Configure vPC principles vPC and N7K module design drawing vPC control plane operations vPC data plane operations Data layer loop prevention (vPC Check) vPC Peer Link Device Failure vPC Peer Failure — Peer-keepalive Link Configure vPCs Experiment 5: N7K vPC (topology introduction) Experiment 5: Configuring HSRP vPC and STP BPDU Spanning Tree Recommended Adjust Spanning Tree configuration vPC Peer Switch feature introduction Autorecovery Delay Restore vPC Object Tracking ARP Synchronization vPC Peer-Gateway Configuring N5K vs N7K vPC Configure EvPC vPC Domain System MAC vPC Role Introduction to vPC Peer Link vPC Member Port Introduction vPC and VDC Interaction between Layer 3 and vPC Layer 3 and vPC design Layer 3 and vPC supported designs Interoperability between STP and vPC Multi-layer vPC and Data Center interconnect FHRP and vPC Orphan-Port Suspend Design of vPC and FEX Switch Port Analyzer (SPAN) Encapsulated Remote SPAN (ERSPAN) ERSPAN configuration Introduction to NetFlow NetFolw configuration |
February 25
| What are Overlays OverlaysVirtualization Types VXLAN Overview VXLAN Frame Format VXLAN VTEP VXLAN Underlay Network – IP Routing VXLAN Forwarding Plane VXLAN Forwarding Packet VXLAN BUM Traffic Handling VTEP Discovery & Address Learning Challenges with Flood-&-Learn VXLAN Deployments What is VXLAN/EVPN Functions of VXLAN/EVPN VXLAN: Flood-&-Learn vs EVPN Control Plane EVPN Primer --- MP-BGP Review EVPN Control Plane – Reachability Distribution EVPN Control Plane -- Host Advertisement EVPN Control Plane -- Host Movement Distributed Anycast Gateway in MP-BGP EVPN VXLAN Routing Symmetric Integrated Routing & Bridging (IRB) Packet Forwarding (Bridge) Packet Forwarding (Route) EVPN Control Plane -- ARP Suppression EVPN Control Plane -- Head-end Replication Flood-&-Learn VS EVPN Control Plane |
March 04 | VxLAN EVPN Parameters Route Distinguishers (RDs). Route Target (RT) EVPN Route types Route type 2 (MAC Only) Route type 2 (MAC/IP) Inclusive Multicast Route type 5 (IP) Route type 5 (IP) has two uses Sample EVPN-Related VRF Configuration for Layer 3 Multitenancy ARP lookup miss with ARP Suppression Multi-pod Multi-fabric/Multi-site Interfabric Option 1: Multi-pod Interfabric Option 2: Multifabric Interfabric Option 3 (Multisite for Layer 3) Interfabric Option 4 (Multisite for Layer 2) VXLAN EVPN MultiPod experimental topology Loopback configuration Interface configuration Ospf routing configuration Pim multicast configuration MP-BGP configuration VXLAN related configurations |
March 11 | VXLAN Evolves as the Control Plane Evolves Inter-X Connectivity Multi-Pod Characteristics – ”The Single” Multi-Pod End-to-End Encapsulation Multi-Pod VXLAN Tunnel Adjacencies Multi-Pod Underlay Extension Multi-Pod BUM Replication Multi-Pod Challenges – ”The Single” Multi-Site Overlay Forwarding VXLAN Multi-Site VXLAN Multi-Site Characteristics VXLAN Multi-Site Underlay Isolation Introducing the Border Gateway VXLAN Tunnel Adjacencies HW/SW Support and Scalability Values BGW-to-Cloud Anycast Border Gateway BUM Replication Modes Control Plane Deployment Considerations Overlay Control Plane (L3 Core, no RS) Selective Advertisements Multi-Site Packet Walk (BUM) VXLAN Multi-Site Packet Walk(Bridging) VXLAN Multi-Site Packet Walk(Routing) VXLAN Multi-Site Topology VXLAN Multi-Site Configuration VXLAN Multi-Site dual BGW scenario VXLAN Multi-Site PIP and VIP VXLAN Multi-Site Route-Type 4 VXLAN Multi-Site Route-Type 3 VXLAN Multi-Site Fabric link failure VXLAN Multi-Site DCI link failure Implement Route Leaking between different VXLAN tenants (added in the previous issue, no longer discussed separately) |
March 18 | Software Defined Networking (SDN(X)) SDN from different manufacturers Misunderstandings about SDN Two different network needs ACI Data Center Product Cisco ACI technical analysis SDN market forecast About the definition of SDN Three major SDN standardization organizations What is OpenFlow Cisco challenges and opportunities SDN architecture core components Problems solved by SDN and OpenFlow Limitations of OpenFlow SDN three main components and goals NFV overview ETSI NFV Reference Architecture Division of labor between NFV and SDN Application examples of SDN in NFV architecture Comprehensive SDN solution Cisco One Solutions Cisco ACI Data Center Problems faced when deploying applications Policy Driven Data Center Approach ACI Fabric Interconnect Matrix Application Definition Example of an “Application” The Policy Theory ACI Logical Architecture Relationship between Consumer and Provider ACI Fabric Design Data center network characteristic Spine-Leaf Architecture Why Spine and Leaf IS-IS Fabric Infrastructure Routing VXLAN Overlay overlay network ACI VXLAN Header Additional ACI VXLAN Header Details VXLAN Tunnel Endpoint (VTEP) ACI Fabric Addressing ACI Fabric Integrated Overlay Decoupled Identity,Location, and Policy Leaf Packet Flow Distributed Forwarding Control Plane - Station Tables Layer 2 and Layer 3 Handing Hardware-based Directed ARP Forwarding Gratuitous ARP and Device Movement Forwarding Bounce ACI Fabric Unicast Forwarding Overview Fast Re-Route Unicast ACI Fabric Multicast Forwarding Overview Endpoint Learning & Lookup EPG Operational Tab - Client Endpoints EPG Operational Tab - Global Endpoints Endpoint Identity Location Learning Example ACI Policy Identification and Enforcement Nexus 9000 Platform: Two Modes Merchant and Custom ASICs Nexus 9508 Hardware Overview Nexus 9500 Platform System Controller Nexus 9500 Platform Supervisor Hardware 8-Slot Modular Chassis Air Flow Fabric Module – Data Plane Scaling for 8-Slot Chassis Deployment of Line Cards in the ACI Fabric Cisco Nexus ACI Modular Line Cards Cisco Nexus ACI Modular Line Cards - Reference Cisco Nexus 9300 Spine Platform Cisco Nexus 9300 Leaf Platform ACI Customer Bundles Configuration Switch Installation best practices |
March 25 | What is APIC APIC controller is attached in-band APIC Clustering -Sharding Technology Effect of Sharding on Reliability APIC Clustering RESTful API Overview Creating an App Network Profile APIC Hardware Ports Fabric Initialization & Maintenance Fabric Login Fabric GUI overview Fabric Initialization & Maintenance ACI Initial Configuration Steps Management Networks Configure OOB and Inband MGMT Configure NTP ACI Policy Types Fabric Policy and Access Policy External interface configuration Configure interface policy Configure interface policy group Configure interface profile Configure switch profile Configure ACI Pools Configure VLANs Pool EPG Mapped to Multiple Ports and VLANs Configure Physical and External Domain Concept of Domain Configure Physical Domain Configure Attachable Entity Profile (AEP) Configure AEP with Interface Policy Group Configure vPC in ACI Fabric ACI logical model Application Network Profiles (ANP) ACI Connection to Outside Network Extend L2 Domain Out of ACI Option A: Extend EPG Option B: Extend Bridge Domain ACI L2 External Connection - STP Interaction ACI Layer 3 outside connections Border Leaves Route Distribution within the ACI Fabric OSPF Peering between ACI and the External Router OSPF High-Availability Design Layer 3 Outside Connection with OSPF Example Integrate L4-L7 Service Graphs Service Graph Definition ACI Terminology With service graph the operational model changes How to Use Sevice Graph Device Definition and Package
|
April 01 | Clear APIC existing configuration Clear the existing configuration of leaf1 Clear the existing configuration of spine1 Initialize APIC configuration Register Leaf and Spine nodes Configure Leaf and Spine node management addresses Configure Leaf and Spine NTP addresses Application layer top-down design Overall design of application layer Application layer requirements Restore APIC empty configuration Create tenant and VRF Create bridge domain T1-BD1 Create T1 tenant HTTP contract Create Common tenant ICMP contract Create T1-ANP under T1 tenant EPG access relationship diagram Register to APIC via vCenter domain Configuring Vmware ESXi host to use APIC's DVS Configure the interface AEP connected to the host Associate EPG to Vmware vCenter Domain Associating the VM to the Port Group of the EPG Test ping Gateway Configuration of OSPF and Interface on DC2-N7K2 Enable MP-BGP in ACI Fabric Determine to create an AEP for the port connected to the N7K based on the situation. Create L3Out external network (EPG of type L3Out) Establish OSPF neighbor with N7K L3Out EPG call accesses the contract of EPG NGINX Implementation of multi-tenant and multi-tier application interoperability Added ACI's Multi-Pod theoretical and experimental explanations |
"Cisco Storage Network" | |
April 8 | SAN, LAN, and Compute Cisco’s Commitment to FC Cisco MDS 9706, 9710 and 9718 Product Portfolio Unmatched Flexibility with Multi-Protocol Innovations Boosting Scale for SAN InfrastructuresThousands of Devices Cisco MDS 9710 Multilayer Director Cisco MDS 9000 16G Fibre Channel Family MDS 9250i Multiservice Fabric Switch Cisco Nexus 5672UP-16G Evolving the Datacenter in Phases MDS 9718 USE CASE CISCO 40G QSFP BIDITRANSCEIVERS 40GE ISL USE CASE Large-Scale Converged Ethernet Deployments The Power of Ecosystem History of storage technology development What are DAS, NAS and SAN hard disk interface protocol NAS architecture Block I/O vs. File I/O Block-Based Protocols SCSI Overview SCSI protocol Storage Area Network (SAN) Storage protocol technology diagram Fibre Channel Overview Standard FC port type Fiber Channel physical address Addressing FCID well-known address N_Port Virtualization(NPIV) N Port Virtualization(NPV) NPV and NPIV relationship FC frame header structure Detailed introduction to FC header field Fiber Channel FC-2 Layer Fiber Channel frame structure Ethernet flow control Fibre Channel Flow Control Fabric Login(FLOGI) Port Login(PLOGI) Process Login(PRLI) Fabric Short Path First Load Balancing over equal cost paths Common Design Practice - Redundant Fabrics Virtual SANs (VSANs) Two Primary Functions of VSANs VSANs and Zones FC configuration experimental part
|
April 15 | The Evolving Data Center Architecture FC over Ethernet (FCoE) FCoE Enables Unified Fabric Before I/O Consolidation After I/O Consolidation High-Speed Ethernet Server Adoption No packet loss using PAUSE technology (802.3x) Data Center Bridging four major component technologies Priority Flow Control Enhanced Transmission Selection DCBX: Data Center Bridging eXchange BCN/QCN FCoE Mapping FCoE packaging FCoE and FIP Fibre Channel Forwarder Fibre Channel Port Types Introduction to FIP Comparison of FC and FCoE configuration examples FIP Virtual Link Establishment FIP VLAN Discovery FIP VLAN Request FIP VLAN Response FIP FCF Discovery FIP FCF discovery solicitation FIP Virtual Link Instantiation FIP FLOGI Request FIP FLOGI ACC FIP Virtual Link Maintenance FIP KeepAlive FCF MAC address FPMAs and SPMAs FCoE interface diagram What is FCoE-NPV FCoE-NPV configuration Details Single Hop Design-OverView Single Hop Design - The CNA Point of View Single Hop Design- The FCoE VLAN Single Hop Design - Converged Links and vPC Multi - Hop Design FCoE configuration experimental part Configure VFC Configure the FCoE link between N5K1 and N5K3 Configure the zone between N5K1 and N5K3 |
"CiscoUCS Unified Computing System" | |
April 22 | Server deployment: rack-mounted Server deployment: Blade Blade Server Deployment: Management Blade Server Deployment: Applications Server deployment virtualization Cisco's solution Traditional blade server architecture Cisco Unified Computing System UCS One of the important innovations: embedded management Important innovation two: Unified Fabric Important innovation three: optimized virtualization environment Important Innovation Four: Memory Expansion Technology Important Innovation No. 5: Stateless Server Important Innovation Six: Hybrid Server Introduction to UCS components UCS series overall architecture UCS Fabric Interconnects Fabric Interconnects-6300 Series Fabric Interconnects-6400 Series Fabric Extender Fabric Extender – 2304XP Fabric Extender detailed introduction Blade Servers: UCS B-Series Chassis – 5108 Back of UCS system UCS system front UCS architecture physical view UCS architecture logical view Blade Servers: UCS B-Series Rack Servers: UCS C-Series Server Adaper Cisco UCS VIC 1340 Cisco UCS VIC 1227 UCS S3260 Storage Server Cisco UCS E-Series Servers UCS simulator installation and initialization UCS simulator download address UCS simulator initialization UCS simulator basic options Configure Fabric Interconnect Configuring FI for high availability Login to UCSM |
April 29 | High availability FI connection High availability cluster High availability cluster initialization Equipment panel Servers panel LAN panel SAN panel VM panel Admin panel Global Policies Chassis Discovery Policy Power Policy Configure DNS Configure time zone and NTP Configure Server Port Discover B200M2 Ethernet End Host Mode disjoint layer-2 Soft-Pinning Hard-Pinning EHM sending rules Ethernet Switching Mode Uplink Configuration Guide UCSM creates VLAN Create Port-Channel (FI-A) Configure LAN Uplinks Manager UCS supported storage FC End-Host Mode Create VSAN and VLAN FC link configuration between devices Configure FI-A Uplink Configure FCoE Uplink Create UUID Pools Create MAC Address Pools Create WWNN Pools Create WWPN Pools Create Management IP Address Pool Create Server Pools |
May 06 | Service Profile Opt-In Models Identify Service Profile Storage Networking SAN Connectivity vNIC/vHBA Placement vMedia Policy Server Boot Order Determine Target PWWN Maintenance Policy Operational Policies Associate Service Profile to the server N5K3 Zone configuration Open-E configuration SANBOOT started successfully Service Profile Template Organizational Relationships and Strategy Design Two types of Templates Install B200M2 ESXi Configure B200M2 vSwitch1 |
CiscoData Center3.0 update announcement: Video summary network disk directory (DC high-quality group announcement has a link address)
How to learn Cisco Data Center 3.0 quickly and effectively: Video summary in the network disk directory
The following extended course video courses (only for through train students) require additional time to study by yourself;
"VMware vSphere 7.0 Virtualization" ---- A must-learn course before taking the main course!
"VMware NSX Network Virtualization"
"Cisco HyperFlex Hyperconvergence"
"Open Source KVM Virtualization"
"LISP in SDA" ---- Recommended learning
"Cloud Management Platform OpenStack Deployment"
"F5 Application Delivery Network 2020 Edition" ---- Key recommended learning
"Docker & Kubernetes 2021 Edition" has now been added to the through-train expansion course ---- Highly recommended learning
The latest recording of "SDN OpenFlow + OpenDaylight 2022 Edition"
QYTang customer service hotline: 400-618-8070
QYTang official website: www.qytang.com
QYTang Network Lab We think more for you