QYTangCiscoData Center Data Center 3.0 Third Period Course Schedule (Saturday Class)

QYTangCiscoData Center Data Center 3.0 Third Period Course Schedule (Saturday Class)

Course start time: October 17, 2020 - January 30, 2021

Lecturer: Ma Haibo
Class time:
Morning: 9:50~12:00 Afternoon: 13:10 ~17:10

"Cisco Nexus Switch"

October 17

Cisco data legacy center network architecture,

Nexus series product line,

October 17

Product introduction of Nexus 7K series,

Nexus series switch port density,

Introduction to Nexus series switch management engine,

Supervisor 3E engine for the N77 series,

Virtual Output Queues,

Nexus series switch management connection mode,

Nexus 7000 Product Label Naming Rules

Nexus 7K Ethernet I/O module classification

Nexus 7K Ethernet M-Series Module

Nexus 7000 M2 I/O modules

Nexus 7000/7700 M3 I/O modules

Nexus 7K Ethernet F-Series Module

Nexus 7000 F3 I/O Modules

Fabric Services Accelerator (FSA) for F3 / M3

F3 card traffic forwarding

Nexus 7700 F4 I/O Modules

I/O Modules interactive mode

Proxy Forwarding method

Lowest Common Denominator approach

F/M card Hardware Table capacity comparison

Crossbar Switch Fabric Module

Nexus 7000 Fabric Module(1)

Nexus 7700 Fabric 2 Module

multi-layer switching matrix

Layer 2 Hardware Forwarding

MAC Table Lookup

Layer 3 Hardware Forwarding

IP FIB TCAM Lookup

Power supply: 6KW AC

Power supply: 7.5KW AC

Power supply: 6KW DC

Power supply non-redundant mode and correct wiring

Power redundancy (N+1 Redundancy)

Grid Redundancy

Power redundancy (Full Redundancy)

Cisco NX-OS Module Architecture

Nexus 7000 / Nexus 7700 NX-OS Features at a Glance

Cisco NX-OS Virtualization

Continuous Operations/HA for Cisco NX-OS

Cisco NX-OS Security

Operational Manageability of Cisco NX-OS

Cisco NX-OS L4-7 Services Integration

Cisco NX-OS Licensing(1)

Cisco NX-OS licensing ordering information

Cisco NX-OS license application and activation

N5000/6000 Data Center aggregation access layer switch

Nexus 5500/5600/6000 usage scenarios

Nexus 5672UP

Nexus 5500 Data and Control Plane Elements

Nexus 5500 Data Plane Elements

Nexus 5500 control plane components

NEXUS 5672UP internal structure

Nexus 5600 Key Forwarding Tables

Nexus 5600 Unicast Table Scaling

Host Table Carving Profiles

MAC/ARP Resource Carving CLI

NEXUS 5600 Series Comparison

NEXUS 5600/6000 Summary

N2K Fabric Extender(FEX)

Cisco Nexus 2000 Series

Nexus 2232PP-10G Fabric Extender

N2K naming scheme

Fabric Extender Terminology

Introduction to packet sending (VN-Tag technology)

Nexus 2000 topology

View module status and version information

Configure management IP address

Configure CDP

Configure power redundancy

Configure NTP (Default VDC)

Configure NTP (None-Default VDC)

Cisco Fabric Services

Configuring CFS Sync NTP

Scheduler Introduction

Configure Scheduler

Introduction to Ethanalyzer

Configure Ethanalyzer

Introduction to Rollback

Configure Rollback

Activate password strength check

Configure SSH server

SSH client

Introduction to CoPP

Introduction to SMARTnet

Introduction to Call home

Alert Group

The types of events that trigger alerts

Configure call home

Cisco VDC architecture

Linux kernel namespace mechanism

Virtualization scalability

Default VDC

Non-Default VDC

Admin VDC

VDC fault domain

VDC resource object

VDC resource sharing

Storage VDC

VDC module association limitations

N7K-M132XP-12 Port Group Introduction

N7K-F132XP-15 Port Group Introduction

Communication between VDCs

VDC Resource Template

VDC hardware utilization: Layer 2 switching

VDC hardware utilization: three-layer switching

Out-of-band VDC management

In-band VDC management

Configure Resource Template

Create VDC

Limit VDC resource usage

Ordinary VDC

Limit associated modules

Associating the interface to the VDC (DC2-N7K-3

CPU Share(CPU share)

Configure CPU Share

Configure Boot Order

Introduction to VDC High Availability(1)

Configuring VDC High Availability

Default VDC Conversion Admin VDC

Switching between VDCs

October 24

The default mode of the port

Basic interface configuration experiment

N7K basic interface configuration

N5K basic interface configuration

Interface description and beacon

MTU configuration introduction

Configure MTU

Understand UDLD technology

Configure UDLD

Simulate UDLD failure

UDLD considerations

Configuring OSPF on DC1-N7K-3

The IP unnumbered feature

Configuring BFD technology for OSPF

Establishment of BFD neighbor relationship

Introduction to BFD theory

Introduction to PSS

Introduction to Graceful Restart

Configure Trunk, VLAN and VTP on DC1-N7K-1

Configure Trunk and VTP on DC1-N5K-1

Adjust STP

Configure MST

Configuring HSRP and VRRP

Summary of L2 / L3 knowledge points

Cisco Nexus switches use Fabric Extenders

Top of Rack wiring and End of Row management

Cisco Nexus 7000 FEX-enabled modules

Cisco Nexus 9000 FEX-enabled modules

Nexus 2348UPQ Overview

Nexus 2232PP-10GE Fabric Extender

Introduction to the package sending process

Network Interface Virtualization (NIV) architecture

VN-Tag port extension

Cisco N7K FEX and VDC

Nexus 2000 SPAN

Introduction to Staic Pinning

Introduction to EtherChannel

Rules for port commands

FEX topologies supported by N7K and N5K

N5K FEX Experiment 1: Single Host FEX (Static Pinning)

N5K FEX Experiment 2: Single Host FEX (EtherChannel)

 

November 7

Port Channel Introduction

Port Channel mode

Hash Options

Experiment 1: Switchport Access

Experiment 2: Switchport Trunk

Experiment 3: Routed Interface

Experiment 4: Routed subinterfaces

Introduction to vPCs

STP vs vPC

Up to 32 Port-Channel(Double-Sided vPC)

Components of vPC Architecture(1)

Components of vPC Architecture(2)

Components of vPC Architecture(3)

Configure vPC policies

vPC and N7K module design drawing

vPC control plane operations

vPC data plane operations

Data layer loop prevention (vPC Check)

vPC Peer Link Device Failure

vPC Peer Failure — Peer-keepalive Link

Configure vPCs

Experiment 5: N7K vPC (topology introduction)

Experiment 5: Configuring HSRP

vPC and STP BPDU

Spanning Tree Recommended

Adjust Spanning Tree configuration

vPC Peer Switch feature introduction

Autorecovery

Delay Restore

vPC Object Tracking

ARP Synchronization

vPC Peer-Gateway

Configuring N5K vs N7K vPC

Configure EvPC

vPC Domain

System MAC

vPC Role

Introduction to vPC Peer Link

vPC Member Port Introduction

vPC and VDC

Interaction between Layer 3 and vPC

Three-tier and vPC design

Layer 3 and vPC supported designs

STP and vPC interoperability

Multi-layer vPC and Data Center interconnection

FHRP and vPC

Orphan-Port Suspend

Design of vPC and FEX

Switch Port Analyzer (SPAN)

Encapsulated Remote SPAN (ERSPAN)

ERSPAN configuration

Introduction to NetFlow

NetFolw configuration

November 14

What are Overlays

Overlays virtualization types

VXLAN Overview

VXLAN Frame Format

VXLAN VTEP

VXLAN Underlay Network – IP Routing

VXLAN Forwarding Plane

VXLAN Forwarding Packet

VXLAN BUM Traffic Handling

VTEP Discovery & Address Learning

Challenges with Flood-&-Learn VXLAN Deployments

What is VXLAN/EVPN

Functions of VXLAN/EVPN

VXLAN: Flood-&-Learn vs EVPN Control Plane

EVPN Primer --- MP-BGP Review

EVPN Control Plane – Reachability Distribution

EVPN Control Plane -- Host Advertisement

EVPN Control Plane -- Host Movement

Distributed Anycast Gateway in MP-BGP EVPN

VXLAN Routing

Symmetric Integrated Routing & Bridging (IRB)

Packet Forwarding (Bridge)

Packet Forwarding (Route)

EVPN Control Plane -- ARP Suppression

EVPN Control Plane -- Head-end Replication

Flood-&-Learn VS EVPN Control Plane

November 21

VxLAN EVPN Parameters

Route Distinguishers (RDs).

Route Target (RT)

EVPN Route types

Route type 2 (MAC Only)

Route type 2 (MAC/IP)

Inclusive Multicast

Route type 5 (IP)

Route type 5 (IP) two uses

Sample EVPN-Related VRF Configuration for Layer 3 Multitenancy

ARP lookup miss with ARP Suppression

Multi-pod

Multi-fabric/Multi-site

Interfabric Option 1: Multi-pod

Interfabric Option 2: Multifabric

Interfabric Option 3 (Multisite for Layer 3)

Interfabric Option 4 (Multisite for Layer 2)

VXLAN EVPN MultiPod experimental topology

Loopback configuration

Interface configuration

Ospf routing configuration

Pim multicast configuration

MP-BGP configuration

VXLAN related configuration

November 28

VXLAN Evolves as the Control Plane Evolves

Inter-X Connectivity

Multi-Pod Characteristics – ”The Single”

Multi-Pod End-to-End Encapsulation

Multi-Pod VXLAN Tunnel Adjacencies

Multi-Pod Underlay Extension

Multi-Pod BUM Replication

Multi-Pod Challenges – ”The Single”

Multi-Site Overlay Forwarding

VXLAN Multi-Site

VXLAN Multi-Site Characteristics

VXLAN Multi-Site Underlay Isolation

Introducing the Border Gateway

VXLAN Tunnel Adjacencies

HW/SW Support and Scalability Values

BGW-to-Cloud

Anycast Border Gateway

BUM Replication Modes

Control Plane Deployment Considerations

Overlay Control Plane (L3 Core, no RS)

Selective Advertisements

Multi-Site Packet Walk (BUM)

VXLAN Multi-Site Packet Walk(Bridging)

VXLAN Multi-Site Packet Walk(Routing)

VXLAN Multi-Site topology

VXLAN Multi-Site configuration

VXLAN Multi-Site dual BGW scenario

VXLAN Multi-Site PIP and VIP

VXLAN Multi-Site Route-Type 4

VXLAN Multi-Site Route-Type 3

VXLAN Multi-Site Fabric link failure

VXLAN Multi-Site DCI link failure

There are two key issues to consider when implementing interoperability between different VXLAN tenants.

"Cisco Nexus 9000 ACI Architecture"

December 5

Software Defined Networking (SDN(X))

SDN from different manufacturers

Misunderstandings about SDN

Two different network needs

ACI Data Center Product

Cisco ACI technical analysis

SDN market forecast

About the definition of SDN

Three major SDN standardization organizations

What is OpenFlow

Cisco challenges and opportunities

SDN architecture core components

Problems SDN and OpenFlow solve

Limitations of OpenFlow

Three main components and goals of SDN

NFV overview

ETSI NFV Reference Architecture

Division of labor between NFV and SDN

Application examples of SDN in NFV architecture

Comprehensive SDN solution

Cisco One Solution

Cisco ACI Data Center

Problems faced when deploying applications

Policy Driven Data Center Approach

ACI Fabric Interconnect Matrix

Application Definition

Example of an “Application”

The Policy Theory

ACI Logical Architecture

Relationship between Consumer and Provider

ACI Fabric Design

Data center network characteristic

Spine-Leaf Architecture

Why Spine and Leaf

IS-IS Fabric Infrastructure Routing

VXLAN Overlay overlay network

ACI VXLAN Header

Additional ACI VXLAN Header Details

VXLAN Tunnel Endpoint (VTEP)

ACI Fabric Addressing

ACI Fabric Integrated Overlay

Decoupled Identity,Location, and Policy

Leaf Packet Flow

Distributed Forwarding Control Plane - Station Tables

Layer 2 and Layer 3 Handing

Hardware-based Directed ARP Forwarding

Gratuitous ARP and Device Movement

Forwarding Bounce

ACI Fabric Unicast Forwarding Overview

Fast Re-Route Unicast

ACI Fabric Multicast Forwarding Overview

Endpoint Learning & Lookup

EPG Operational Tab - Client Endpoints

EPG Operational Tab - Global Endpoints

Endpoint Identity Location Learning Example

ACI Policy Identification and Enforcement

Nexus 9000 Platform: Two Modes

Merchant and Custom ASICs

Nexus 9508 Hardware Overview

Nexus 9500 Platform System Controller

Nexus 9500 Platform Supervisor

Hardware 8-Slot Modular Chassis Air Flow

Fabric Module – Data Plane Scaling for 8-Slot Chassis

Deployment of Line Cards in the ACI Fabric

Cisco Nexus ACI Modular Line Cards

Cisco Nexus ACI Modular Line Cards - Reference

Cisco Nexus 9300 Spine Platform

Cisco Nexus 9300 Leaf Platform

ACI Customer Bundles Configuration

Switch Installation best practices

December 12

What is APIC

APIC controller is attached in-band

APIC Clustering -Sharding Technology

Effect of Sharding on Reliability

APIC Clustering

RESTful API Overview

Creating an App Network Profile

APIC Hardware Ports

Fabric Initialization & Maintenance

Fabric Login

Fabric GUI overview

Fabric Initialization & Maintenance

ACI Initial Configuration Steps

Management Networks

Configure OOB and Inband MGMT

Configure NTP

ACI Policy Types

Fabric Policy and Access Policy

External interface configuration

Configure interface policy

Configure interface policy group

Configure interface profile

Configure switch profile

Configure ACI Pools

Configure VLANs Pool

EPG Mapped to Multiple Ports and VLANs

Configure Physical and External Domain Concept of Domain

Configure Physical Domain

Configure Attachable Entity Profile(AEP)

Configure AEP with Interface Policy Group

Configure vPC in ACI Fabric

ACI logical model

Application Network Profiles (ANP)

ACI Connection to Outside Network

Extend L2 Domain Out of ACI

Option A: Extend EPG

Option B: Extend Bridge Domain

ACI L2 External Connection - STP Interaction

ACI Layer 3 outside connections

Border Leaves

Route Distribution within the ACI Fabric

OSPF Peering between ACI and the External Router

OSPF High-Availability Design

Layer 3 Outside Connection with OSPF Example

Integrated L4-L7 Service Graphs

Service Graph Definition

ACI Terminology

With service graph the operational model changes

How to Use Sevice Graph

Device Definition and Package

December 19

Clear existing APIC configuration

Clear the existing configuration of leaf1

Clear the existing configuration of spine1

Initialize APIC configuration

Register Leaf and Spine nodes

Configure Leaf and Spine node management addresses

Configure Leaf and Spine NTP addresses

Top-down design of application layer Overall design of application layer

Application layer requirements

Restore APIC empty configuration

Create tenant and VRF

Create bridge domain T1-BD1

Create T1 tenant HTTP contract

Create Common tenant ICMP contract

Create T1-ANP under T1 tenant

EPG access relationship diagram

Register to APIC via vCenter domain

Configuring a Vmware ESXi host to use APIC's DVS

Configure the interface AEP that connects to the host

Associate EPG to Vmware vCenter Domain

Port Group to associate VM to EPG

Test ping Gateway

Recommended parameters for deploying transparent firewall BD

Transparent mode Firewall initial configuration parameters

Create Function Profiles For transparent

Apply Service Graph template to EPG

Configuration of OSPF and Interface on DC2-N7K2

Enable MP-BGP in ACI Fabric

Determine to create an AEP for the port connected to the N7K based on the situation

Create L3Out external network (EPG of L3Out type)

Establish OSPF neighbor with N7K

L3Out EPG calls to access the EPG NGINX contract

Implementation of multi-tenant and multi-tier application interoperability

"Cisco Storage Network"

December 26

SAN, LAN, and Compute

Cisco’s Commitment to FC

Cisco MDS 9706, 9710 and 9718 Product Portfolio

Unmatched Flexibility with Multi-Protocol Innovations

Boosting Scale for SAN InfrastructuresThousands of Devices

Cisco MDS 9710 Multilayer Director

Cisco MDS 9000 16G Fibre Channel Family

MDS 9250i Multiservice Fabric Switch

Cisco Nexus 5672UP-16G

Evolving the Datacenter in Phases

MDS 9718 USE CASE

CISCO 40G QSFP BIDITRANSCEIVERS

40GE ISL USE CASE

Large-Scale Converged Ethernet Deployments

The Power of Ecosystem

History of storage technology development

What are DAS, NAS and SAN

hard disk interface protocol

NAS architecture

Block I/O vs. File I/O

Block-Based Protocols

SCSI Overview

SCSI protocol

Storage Area Network (SAN)

Storage protocol technology diagram

Fibre Channel Overview

Standard FC port types

Fiber Channel physical address

Addressing FCID

well-known address

N_Port Virtualization(NPIV)

N Port Virtualization(NPV)

NPV and NPIV relationship

FC frame header structure

Detailed introduction to FC header field

Fiber Channel FC-2 Layer

Fiber Channel frame structure

Ethernet flow control

Fibre Channel Flow Control

Fabric Login(FLOGI)

Port Login(PLOGI)

Process Login(PRLI)

Fabric Short Path First

Load Balancing over equal cost paths

Common Design Practice - Redundant Fabrics

Virtual SANs (VSANs)

Two Primary Functions of VSANs

VSANs and Zones

FC configuration experimental part

January 9

The Evolving Data Center Architecture

FC over Ethernet (FCoE)

FCoE Enables Unified Fabric

Before I/O Consolidation

After I/O Consolidation

High-Speed Ethernet Server Adoption

No packet loss (802.3x) using PAUSE technology

Data Center Bridging four major component technologies

Priority Flow Control

Enhanced Transmission Selection

DCBX: Data Center Bridging eXchange

BCN/QCN

FCoE Mapping

FCoE packaging

FCoE and FIP

Fibre Channel Forwarder

Fibre Channel Port Types

Introduction to FIP

Comparison of FC and FCoE configuration examples

FIP Virtual Link Establishment

FIP VLAN Discovery

FIP VLAN Request

FIP VLAN Response

FIP FCF Discovery

FIP FCF discovery solicitation

FIP Virtual Link Instantiation

FIP FLOGI Request

FIP FLOGI ACC

FIP Virtual Link Maintenance

FIP KeepAlive

FCF MAC address

FPMAs and SPMAs

FCoE interface diagram

What is FCoE-NPV

FCoE-NPV configuration Details

Single Hop Design-OverView

Single Hop Design - The CNA Point of View

Single Hop Design- The FCoE VLAN

Single Hop Design - Converged Links and vPC

Multi - Hop Design

FCoE configuration experimental section

Configure VFC

Configure the FCoE link between N5K1 and N5K3

Configure the zone between N5K1 and N5K3

"Cisco UCS Unified Computing System"

January 16

Server deployment: rack-mounted

Server deployment: Blade

Blade Server Deployment: Management

Blade Server Deployment:Application

Server deployment virtualization

Cisco's solution

Traditional blade server architecture

Cisco Unified Computing System UCS

One of the important innovations: embedded management

Important innovation two: Unified Fabric

Important innovation three: optimized virtualization environment

Important Innovation Four: Memory Expansion Technology

Important Innovation 5: Stateless Server

Important Innovation Six: Hybrid Server

Introduction to UCS components

Overall architecture of UCS series

UCS Fabric Interconnects

Fabric Interconnects-6300 Series

Fabric Interconnects-6400 Series

Fabric Extender

Fabric Extender – 2304XP

Fabric Extender detailed introduction

Blade Servers:

UCS B-Series Chassis – 5108

Back of UCS system

UCS system front

UCS Architecture Physical View

UCS architecture logical view

Blade Servers: UCS B-Series

Rack Servers: UCS C-Series

Server Adaper

Cisco UCS VIC 1340

Cisco UCS VIC 1227

UCS S3260 Storage Server Cisco

UCS E-Series Servers

UCS simulator installation and initialization

UCS simulator download address

UCS simulator initialization

UCS Simulator Basic Options

Configure Fabric Interconnect

Configuring FI for high availability

Login to UCSM

January 23

High availability FI connections

High availability cluster

High availability cluster initialization

Equipment panel

Servers panel

LAN panel

SAN panel

VM panel

Admin panel

Global Policies

Chassis Discovery Policy

Power Policy

Configure DNS

Configure time zone and NTP

Configure Server Port

Discover B200M2

Ethernet End Host Mode

disjoint layer-2

Soft-Pinning

Hard-Pinning

EHM sending rules

Ethernet Switching Mode

Uplink Configuration Guide

UCSM creates VLAN

Create Port-Channel(FI-A)

Configure LAN Uplinks Manager

UCS supported storage

FC End-Host Mode

Create VSANs and VLANs

Inter-device FC link configuration

Configure FI-A Uplink

Configure FCoE Uplink

Create UUID Pools

Create MAC Address Pools

Create WWNN Pools

Create WWPN Pools

Create Management IP Address Pool

Create Server Pools

January 30

Service Profile

Opt-In Models

Identify Service Profile

Storage

Networking

SAN Connectivity

vNIC/vHBA Placement

vMedia Policy

Server Boot Order

Determine Target PWWN

Maintenance Policy

Operational Policies

Associate Service Profile to server

N5K3 Zone Configuration

Open-E configuration

SANBOOT started successfully

Service Profile Template

Organizational Relationships and Strategy Design

Two types of Templates

Install B200M2 ESXi

Configure B200M2 vSwitch1

 

CiscoData Center 3.0 update announcement: video summary network disk directory (DC high-quality group announcement has the link address)

How to learn Cisco Data Center 3.0 quickly and effectively: Video summary in the network disk directory

The following extended course video courses (only for through train students) require additional time to study by yourself;

"VMware vSphere 7.0 Virtualization" ---- A must-learn course

"VMware NSX Network Virtualization"

"Cisco HyperFlex Hyperconvergence"

"Open Source KVM Virtualization"

"LISP in SDA" ---- Recommended study

"Cloud Management Platform OpenStack Deployment"

"F5 Application Delivery Network 2020 Edition" separately paid course ---- Recommended learning

 

QYTang customer service hotline:400-618-8070

QYTang official website: www.qytang.com

QYTang Network Lab We think more for you